? ? ? ?CloudMatrix 6657FϵÁÐÊÇjiuyou.comÃæÏòÊý¾ÝÖÐÐÄÍÆ³öµÄÐÂÒ»´ú¸ßÐÔÄÜ¡¢¸ßÃܶȡ¢µÍʱÑÓÍòÕ×ÒÔÌ«Íø½»»»»ú£¨CloudMatrix£¬¼ò³ÆCM£©¡£CloudMatrix 6657F ²ÉÓÃÏȽøµÄÓ²¼þ½á¹¹Éè¼Æ£¬Ìṩ¸ßÃÜ 10GE ¶Ë¿Ú½ÓÈ룬֧³Ö 40GE ÉÏÐж˿ڣ¬Èí¼þƽ̨»ùÓÚÐÂÒ»´úµÄ ²Ù×÷ϵͳ£¬Ö§³Ö·á¸»µÄÊý¾ÝÖÐÐÄÌØÐԺ͸ßÐÔÄܵĶѵþ£¬·çµÀ·½Ïò¿ÉÒÔÁé»îÑ¡Ôñ¡£CloudMatrix 6657F ¿ÉÒÔÓëÊý¾ÝÖÐÐĺËÐĽ»»»»úCloudMatrix 16600 »ò CloudMatrix 12500E ÅäºÏ¹¹½¨µ¯ÐÔ¡¢ÐéÄâºÍ¸ßÆ·ÖʵÄÔÆÊ±´úÊý¾ÝÖÐÐÄÍøÂ磬Âú×ãÔÆÊ±´úÊý¾ÝÖÐÐĶÔÍøÂçµÄÐèÇó¡£
? ? ? ? CloudMatrix 6657F ϵÁн»»»»ú¶¨Î»ÓÚÊý¾ÝÖÐÐĵĸßÃÜÍòÕ×½ÓÈ룬°ïÖúÆóÒµºÍÔËÓªÉ̹¹½¨ÃæÏòÔÆ¼ÆËãʱ´úµÄÊý¾ÝÖÐÐÄÍøÂçÆ½Ì¨£¬Ò²¿ÉÒÔÓÃÓÚÔ°ÇøÍøµÄºËÐÄ»ò»ã¾Û¡£
? ? ? ? CloudMatrix 6657F ϵÁн»»»»ú°üÀ¨CloudMatrix 6657F-48S6CQÒ»¿î»úÐÍ£¬¿ÉÒÔͨ¹ýÅäÖò»Í¬·çÏòµÄµçÔ´ºÍ·çÉÈÀ´ÊµÏÖ·çÏòǰ½øºó³ö»òºó½øÇ°³öÁ½ÖÖģʽ¡£
? ? ? ? CloudMatrix 6657F-48S6CQ½»»»»úÌṩ 48 ¸ö 10GE SFP+½Ó¿Ú£¬6 ¸ö100GE QSFP28 ½Ó ¿Ú , »ò 6 ¸ö 40GE QSFP+½Ó¿Ú¡£Ö§³Öǰ½øºó³ö»òºó½øÇ°³öÉ¢ÈÈ·çµÀ¡£
¸ßÃܶÈÍòÕ×½ÓÈ룬ÈÝÁ¿³¬Èº
l?? ¸ßÐÔÄÜ TOR ½»»»»ú£¨1U£©£¬L2/L3 È«ÏßËÙת·¢£»
l?? ×î´óÌṩ 48 ¸ö 10GE ½Ó¿Ú£¬Âú×ãÍòÕ×·þÎñÆ÷¸ßÃܽÓÈëÐèÇó£»
l?? ×î´óÖ§³Ö 6¸ö 100GE ¸ßÐÔÄÜQSFP28 ½Ó¿Ú£¬QSFP28 ½Ó¿ÚÔÊÐí×÷Ϊ 1 ¸ö 40GE QSFP+½Ó¿Ú£¬ÌṩÁé»îµÄ×éÍøÄÜÁ¦£»100GEÉÏÐÐÓë CloudMatrix 16600 ϵÁй²Í¬¹¹½¨ÎÞ×èÈûµÄÍøÂçÆ½Ì¨¡£
¸ß¿É¿¿³¤¾à¶Ñµþ£¬ÐÔÄÜ׿Խ
Òµ½çÁìÏÈ 16 ̨¶Ñµþ¼¼Êõ£º
l?? 16 ̨½»»»»ú¶ÑµþÌṩ×î´ó 768 ¸ö 25GE ½ÓÈë¶Ë¿Ú£¬Âú×ãÊý¾ÝÖÐÐĸßÃܶȷþÎñÆ÷½ÓÈëÐèÇó£»
l?? ¶ą̀É豸ÐéÄ⻯Ϊһ̨Âß¼É豸,¹¹½¨¿ÉÀ©Õ¹¡¢Ò×¹ÜÀíµÄÊý¾ÝÖÐÐÄÍøÂçÆ½Ì¨£»
l?? ¶ÑµþϵͳʵÏÖ¿ØÖÆÆ½ÃæºÍÊý¾ÝÆ½ÃæÈßÓ౸·Ý£¬±ÜÃâÁ˵¥µã¹ÊÕϵķçÏÕ£¬¼«´óµÄÔöÇ¿ÁËϵͳµÄ¿É¿¿ÐÔ¡£
l?? ³¬³¤¾à¶Ñµþ£º
l?? ÒµÎñ¿Ú¸´ÓÃΪ¶Ñµþ¿Ú£¬²»½ö¿ÉÒÔʵÏÖ»ú¼ÜÄÚ¡¢¿ç»ú¼ÜµÄ¶Ñµþ£¬Í¬Ê±Ò²Ö§³Ö¿çÇøÓòµÄÔ¶¾àÀë¶Ñµþ£»
l?? ¸ù¾Ýʵ¼Ê×éÍø¹æÄ£Áé»î·ÖÅäÒµÎñ´ø¿íºÍ¶Ñµþ´ø¿í£¬ºÏÀíÅäÖÃÍøÂç×ÊÔ´¡£
¿çÉ豸Á´Â·¾ÛºÏ£¬¸ßЧ¿É¿¿
l?? CloudMatrix 6657F ϵÁÐÖ§³Ö¿çÉ豸Á´Â·¾ÛºÏ M-LAG£¨Multichassis Link Aggregation Group£©£¬Äܹ»ÊµÏÖ¶ą̀É豸¼äµÄÁ´Â· ¾ÛºÏ£¬´Ó¶ø°ÑÁ´Â·¿É¿¿ÐÔ´Óµ¥°å¼¶Ìáµ½É豸¼¶£»
l?? ¶à»îϵͳ£¬Ò»·½ÃæË«¹éϵͳʵÏÖÁ÷Á¿¸ºÔØ·Öµ££¬ÁíÒ»·½ÃæÏµÍ³¶à»î¡¢Èȱ¸·Ý±£»¤£¬ÏµÍ³¸ü¿É¿¿£»
l?? M-LAG µÄ¸÷½ÚµãÉ豸¿É¶ÀÁ¢Éý¼¶£¬Éý¼¶¹ý³ÌÖÐÆäËü½Úµã³Ð½ÓÒµÎñת·¢£¬ÊµÏÖÒµÎñÁãÖжϣ»
l?? ×éÍøÁé»î£¬ÆÕͨÒÔÌ«ÍøÂç¡¢TRILL¡¢VxLAN ÒÔ¼° IP ÍøÂçµÄË«¹é½ÓÈë¾ù¿É²ÉÓà M-LAG ½ÓÈ뷽ʽ£»
l?? È«ÃæµÄ¿çÉ豸Á´Â·¾ÛºÏ¼¼Êõ£¬½«É豸×éÍøµÄñîºÏ¹ØÏµ´Ó¿ØÖÆÃæ¶ÑµþÌáÉýΪÐÒé¼¶ M-LAG ÔÙµ½ÎÞñîºÏµÄ×îÖÕÐÎ̬ M-Lag Lite£¬ ʵÏÖ·þÎñÆ÷Ë«»î½ÓÈëºÍ½»»»»úÁãÖжÏÉý¼¶£¬È·±£ÒµÎñ 7*24 СʱÔÚÏß¡£
ÐéÄ⻯Ӳ¼þÍø¹Ø£¬¿ìËÙ²¿Êð
l?? CloudMatrix 6657F ϵÁпÉÒÔÓëÒµ½çÖ÷Á÷µÄÐéÄ⻯ƽ̨ÅäºÏ£¬×÷Ϊ Overlay ÐéÄâ»¯ÍøÂ磨VxLAN/NVGRE£©µÄ¸ßÐÔÄÜÓ²¼þÍø¹Ø£¬Ö§³Å¸ß´ï 16M ¶à×â»§µÄÊý¾ÝÖÐÐÄÔËÓª£»
l?? CloudMatrix 6657F ϵÁÐ×÷ Overlay ÍøÂçµÄÓ²¼þÍø¹ØÊ±£¬¿ÉÒÔͨ¹ý Open API ÓëÔÆÆ½Ì¨¿ª·Å¶Ô½Ó£¬ÊµÏÖÈí¼þÍøÂçºÍÓ²¼þÍøÂçµÄͳһ¹ÜÀí£»
l?? Ó²¼þÐéÄâ»¯Íø¹Ø·½°¸ÎÞÐè¸Ä¶¯¿Í»§ÏÖÍø£¬ÊµÏÖÒµÎñµÄ¿ìËÙ²¿Êð£¬Í¬Ê±±£»¤ÍøÂçͶ×Ê£»
l?? Ö§³Ö BGP-EVPN ×÷Ϊ VXLAN µÄ¿ØÖÆÆ½Ã棬¼ò»¯DCÄÚ¡¢DC¼äµÄ VXLAN µÄÅäÖá£
¿ª·Å¿É±à³ÌÍøÂ磬Áé»î¶¨ÖÆ
l?? CloudMatrix 6657F ϵÁн»»»»úÄÚÖÃµÄ ¿ª·Å¿É±à³Ì Ä£¿é£¬ÊµÏÖÉ豸¿ØÖÆÃæµÄ¿É±à³Ì£»
l?? ¿ª·Å¿É±à³ÌÄ£¿é ÌṩÁ˷ḻµÄ Open API ½Ó¿Ú£¬¿É±»Òµ½çÖ÷Á÷ÔÆÆ½Ì¨£¨º¬ÉÌÒµÔÆÆ½Ì¨ºÍ¿ªÔ´ÔÆÆ½Ì¨£©ºÍµÚÈý·½ Controller Éî¶È¼¯³É£¬ Ö§³ÖÒµÎñ¶ÔÍøÂçµÄÁé»î¶¨ÖƺÍ×Ô¶¯»¯¹ÜÀí£»
l?? Óû§»òµÚÈý·½¿ª·¢ÉÌ¿ÉÀûÓà Open API ½Ó¿Ú£¬¿ª·¢ºÍ²¿ÊðרÓõÄÍøÂç¹ÜÀí²ßÂÔ£¬´Ó¶øÑ¸ËÙµØÊµÏÖÒµÎñ¹¦ÄÜÀ©Õ¹¡¢×Ô¶¯²¿ÊðºÍÉ豸µÄÖÇÄÜ»¯¹ÜÀí£¬ÊµÏÖ×Ô¶¯»¯ÔËά£¬½µµÍ¹ÜÀí³É±¾£»
l?? ×Ô¶¯»¯¹¤¾ß£¬jiuyou.com CloudMatrix 6657F ϵÁн»»»»úÖ§³Ö Ansible ×Ô¶¯»¯¹ÜÀíÔËά¹¤¾ß£¬ÊµÏÖÎïÀí¡¢ÐéÄâÍøÂçµÄͳһ·¢·Å£»
l?? ¿ª·Å¿É±à³ÌÄ£¿é ÖÂÁ¦ÓÚÊý¾ÝÖÐÐÄÒµÎñºÍÍøÂçµÄÎÞ·ìÈںϣ¬Ìá¹©ÃæÏòÒµÎñµÄÈí¼þ¶¨ÒåÍøÂç¡£
É豸ÁãÅäÖò¿Êð£¬×Ô¶¯ÔËά
l?? CloudMatrix 6657F ϵÁн»»»»úÖ§³Ö ZTP£¨Zero Touch Provisioning£©ÐÒ飬¿ÉÒÔÎļþ·þÎñÆ÷»ñÈ¡°æ±¾Îļþ²¢×Ô¶¯¼ÓÔØ£¬ÊµÏÖÉ豸µÄÃâÏÖ³¡ÅäÖúͲ¿Ê𣬴Ӷø½µµÍÈËÁ¦³É±¾£¬ÌáÉý²¿ÊðЧÂÊ£»
l?? ZTP ¹¦ÄÜÖ§³ÖÄÚǶ½Å±¾ÓïÑÔ£¬²¢Í¨¹ý Open API ¿ª·Å¸øÓû§£¬Êý¾ÝÖÐÐÄÓû§¿ÉʹÓÃÆäÊìϤµÄ½Å±¾ÓïÑÔ£¨Python µÈ£©ÊµÏÖ¶ÔÍøÂçÉ豸µÄͳһÅäÖã»
l?? ZTP ʵÏÖÐÂÉ豸ÅäÖÃʱ¼äÓëÉ豸ÊýÁ¿¡¢µØÓò·Ö²¼½âñËõ¶ÌÒµÎñÉÏÏßʱ¼ä£¬Ìá¸ßÁËÒµÎñÉÏÏßЧÂÊ¡£
ÑϸñµÄǰºó·çµÀ£¬¸ßЧ½ÚÄÜ
Áé»îµÄǰºó/ºóǰ·çµÀÉè¼Æ£º
l?? ²ÉÓÃÑϸñµÄǰºó·çµÀÉè¼Æ£¬Ö§³ÖÀäÈÈ·çµÀÍêÈ«¸ôÀ룬ÌáÉýÉ¢ÈȵÄЧÂÊ£¬Âú×ãÊý¾ÝÖÐÐÄ»ú·¿Éè¼ÆÒªÇó£»
l?? ͨ¹ýÑ¡Åä·çÉȺ͵çÔ´Ä£¿é£¬Áé»îÖ§³ÖǰºóºÍºóǰ·çµÀ£»
l?? Ö§³ÖµçÔ´ºÍ·çÉÈÈßÓàÅäÖ㬱£ÕÏÒµÎñÎÞ¼ä¶ÏÔËÐС£´´ÐµĽÚÄܼ¼Êõ£º
l?? ʹÓýÚÄÜоƬ£¬ÖÇÄܵķçÉȵ÷ËÙ·½°¸£¬Ö§³Öʵʱ¹¦ºÄ¼ì²â£¬Îª¿Í»§½µµÍÔËά³É±¾£¬´òÔìÂÌÉ«Êý¾ÝÖÐÐÄ¡£
ÖÇÄÜÎÞËð£¬ÌáÉý¸ßÐÔÄܼÆËã¿É¿¿ÐÔ
l?? ·Ö²¼Ê½ÏµÍ³ÖУ¬RoCE ¼¼Êõ³ÉΪÖ÷Á÷£¬Îª±£Ö¤ÍÌÍÂÂÊ£¬¶Ô¶ª°üÓÐÑϸñÒªÇó£»ÖÇÄÜÎÞËðÊý¾ÝÖÐÐÄÍøÂ磬Ϊ·Ö²¼Ê½ÏµÍ³Ìṩ ¸ßÍÌÍ¡¢¸ß¿É¿¿¡¢µÍʱÑÓµÄת·¢ÄÜÁ¦£¬±ÈÒµ½çƽ¾ùʱÑÓµÍ 25%£»
l?? Ö§³Ö VIQ ¼¼Êõ£¬¶¨ÖÆËã·¨£¬»ùÓÚÒµÎñ¶¨ÖÆÐéÄâ¶ÓÁУ¬¾«Ï¸»¯¹ÜÀí£¬Ô¤ÅÐÉÏÏÂÐжÓÁÐÓµÈû£¬Ïû³ýÉ豸ÄÚת·¢¶ª°ü£»
l?? Ö§³Ö AI ECN VXLAN Overlay µÈ¼¼Êõ£¬Ô¤ÅÐÍøÂçÓµÈû£¬¿ìËÙ·´À¡£¬¼õÉÙÍøÂ綪°üÒýÆðµÄÖØ´«ºÍÍÌÍÂÁ¿Ï½µ£¬ÔÚʱÑÓºÍÍÌÍÂÁ¿Ö®¼äÈ¡µÃ×î´óÊÕÒæ£»
l?? Ö§³Ö¶¯Ì¬¸ºÔؾùºâ£¨DLB£©£¬»ùÓÚ ECMP ×éºÍ LAG ×é½øÐж¯Ì¬¸ºÔؾùºâ¡£
ָʾµÆÍêÃÀ³ÊÏÖ£¬ÔËά¼òµ¥
ÇåÎúµÄָʾµÆ£º
l?? Ö§³Ö¶Ë¿Ú״̬¡¢¶Ë¿ÚËÙÂʵÈÐÅÏ¢µÄÍêÕû³ÊÏÖ£¬´´Ð嵀 100GE ¶Ë¿ÚָʾµÆ£¬¿ÉÒÔÇåÎúÏÔʾËùÓÐ×Ó¶Ë¿Ú״̬£»
l?? Ç°Ãæ°åºÍºóÃæ°åͬ²½ÏÔʾϵͳ״̬£¬±ãÓÚ´ÓÈÎÒâ·½Ïòά»¤£»
l?? Ö§³ÖÔ¶³Ì¶¨Î»¹¦ÄÜ£¬ÔÚÍø¹Ü/¿ØÖÆÌ¨ÉÏ¿ÉÒÔµãÁÁÐèҪά»¤É豸µÄÔ¶³Ì¶¨Î»Ö¸Ê¾µÆ£¬±ãÓÚÔÚÓµ¼·µÄÉ豸¼ä׼ȷ¶¨Î»É豸¡£
l?? ά»¤¼òµ¥£º
l?? ¹ÜÀí½Ó¿Ú/·çÉÈ/µçԴλÓÚ½»»»»úµÄÕýÃæ£¬±ãÓÚά»¤£»
l?? Êý¾Ý½Ó¿ÚλÓÚ½»»»»úµÄºó²à£¬ºÍ·þÎñÆ÷ͬÏò£¬±ãÓÚ×ßÏß¡£
ÏîÄ¿ | CloudMatrix? 6657F-48S8CQ |
10GE ? SFP+ ½Ó¿Ú | 48 |
40/100GE ? QSFP28 ½Ó¿Ú | 6 |
½»»»ÈÝÁ¿ | 4.8Tbps/76.8Tbps |
°üת·¢ÂÊ | 2,000Mpps |
·çµÀÀàÐÍ | ±ê׼ǰºó»òºóǰ·çµÀ |
É豸ÐéÄ⻯ | Ö§³Ö ? M-LAG ÖÇÄܶѵþ |
ÍøÂçÐéÄ⻯ | Ö§ ³Ö ? VXLAN routing ºÍ ? VXLAN bridging |
Ö§ ³Ö ? BGP-EVPN | |
Ö§³Ö QinQ ? access VXLAN | |
Êý¾ÝÖÐÐÄ»¥Áª | Ö§³Ö VxLAN Mapping£¬ÊµÏÖ¶à DC ¶þ²ã»¥Í¨ |
ÍøÂçÈÚºÏ | Ö§³Ö RDMA ? ºÍ RoCE£¨RoCE ? v1 ºÍ RoCE ? v2£© |
Ö§³Ö FCoE | |
Ö§³Ö DCBX¡¢PFC¡¢ETS | |
¿É±à³ÌÌØÐÔ | Ö§³Ö ? OpenFlow ÐÒé |
Ö§³Ö ¿ª·Å¿É±à³Ì | |
Ö§³Ö Ansible ×Ô¶¯»¯ÅäÖã¬Module ¿ªÔ´·¢²¼ | |
Á÷Á¿·ÖÎö | Ö§³Ö ? Netstream ¹¦ÄÜ |
Ö§³Ö ¿ª·Å¿É±à³Ì | |
VLAN | Ö§³Ö Ansible ×Ô¶¯»¯ÅäÖã¬Module ¿ªÔ´·¢²¼ |
Ö§³Ö default ? VLAN | |
Ö§³Ö QinQ | |
Ö§³Ö MUX VLAN | |
Ö§³Ö GVRP | |
MAC µØÖ·±í | Ö§³Ö MAC µØÖ·×Ô¶¯Ñ§Ï°ºÍÀÏ»¯ |
Ö§³Ö¾²Ì¬¡¢¶¯Ì¬¡¢ºÚ¶´ MAC ±íÏî | |
Ö§³ÖÔ´ MAC µØÖ·¹ýÂË | |
Ö§³Ö»ùÓÚ¶Ë¿ÚºÍ VLAN ? µÄ MAC µØÖ·Ñ§Ï°ÏÞÖÆ | |
IP ·ÓÉ | Ö§³Ö RIP¡¢OSPF¡¢ISIS¡¢BGP µÈ IPv4 ? ¶¯Ì¬Â·ÓÉÐÒé |
| Ö§³Ö ? RIPng¡¢OSPFv3¡¢ISISv6¡¢BGP4+µÈ IPv6 ? ¶¯Ì¬Â·ÓÉÐÒé | |
IPv6 | IPv6 ? VXLAN over IPv4 |
Ö§³Ö IPv6 ? ND£¨Neighbor ? Discovery£© | |
Ö§³Ö PMTU ? ·¢ÏÖ£¨Path ? MTU Discovery£© | |
Ö§³Ö IPv6 ? µÄ TCP¡¢Ping ¡¢Tracert¡¢Socket¡¢UDP¡¢RawIP | |
×é²¥ | Ö§³Ö IGMP¡¢PIM-SM ? µÈ×鲥·ÓÉÐÒé |
Ö§³Ö IGMP ? Snooping | |
Ö§³Ö Igmp ? snooping proxy | |
Ö§³Ö×é²¥³ÉÔ±½Ó¿Ú¿ìËÙÀ뿪 | |
Ö§³Ö×é²¥Á÷Á¿ÒÖÖÆ | |
Ö§³Ö×é²¥ VLAN | |
Ö§³Ö×é²¥ VxLAN | |
MPLS | Ö§³Ö |
¿É¿¿ÐÔ | Ö§³Ö LACP |
Ö§³Ö STP¡¢RSTP¡¢PVST ºÍ MSTP | |
Ö§³Ö BPDU ? ±£»¤ | |
Ö§³Ö ? SmartLink ¼°¶àʵÀý | |
Ö§³ÖÓ²¼þ BFD£¨Bidirectional ? Forwarding Detection£©£¬×îС ? 3.3ms ·¢°ü¼ä¸ô | |
Ö§³Ö VRRP¡¢VRRP ¸ºÔØ·Öµ£¡¢BFD ? for VRRP | |
Ö§³Ö BFD ? for BGP/IS-IS/OSPF/¾²Ì¬Â·ÓÉ | |
Ö§³Ö BFD ? for VXLAN | |
DLDP | |
ERPS ÒÔÌ«»·±£»¤ÐÒ飨G.8032£© | |
¾«Ï¸»¯Î¢·Ö¶Î°²È«¸ôÀë | |
QoS | Ö§³Ö»ùÓÚ Layer2 ? ÐÒéÍ·¡¢Layer3 ? ÐÒé¡¢Layer4 ? ÐÒéÓÅÏȼ¶µÈµÄ×éºÏÁ÷·ÖÀà |
Ö§³Ö ACL¡¢CAR¡¢Remark¡¢Schedule ? µÈ¶¯×÷ | |
Ö§³Ö PQ¡¢DRR¡¢PQ+DRR ? µÈ¶ÓÁе÷¶È·½Ê½ | |
Ö§³Ö WRED¡¢Î²¶ªÆúµÈÓµÈû±ÜÃâ»úÖÆ | |
Ö§³ÖÁ÷Á¿ÕûÐÎ | |
ÔËά | Ö§³ÖÈ«ÍøÂ·¾¶Ì½²â |
Ö§³Ö ? Telemetry | |
Ö§³Ö INT¡¢ERSPAN ? ÔöÇ¿ | |
Ö§³Ö»º´æµÄ΢ͻ·¢×´Ì¬Í³¼Æ | |
Ö§³Ö ? VXLAN OAM: VXLAN ping, VXLAN tracert | |
ÖÇÄÜÎÞËð¹¦ÄÜ | ECN Ö§³Ö Vxlan Overlay ³¡¾° |
VIQ:ÎÞ¶ª°ü»º´æ×Ô¶¯ÅäÖà | |
AI ECN | |
DLB: ¶¯Ì¬¸ºÔؾùºâ | |
ÅäÖÃÓëά»¤ | Ö§³Ö ? Console¡¢Telnet¡¢SSH µÈÖÕ¶Ë·þÎñ |
Ö§³Ö ? SNMPv1/v2/v3 µÈÍøÂç¹ÜÀíÐÒé | |
Ö§³Öͨ¹ý FTP¡¢TFTP ·½Ê½ÉÏÔØ¡¢ÏÂÔØÎļþ | |
Ö§³Ö ? BootROM Éý¼¶ºÍÔ¶³ÌÔÚÏßÉý¼¶ | |
Ö§³ÖÈȲ¹¶¡ | |
Ö§³ÖÓû§²Ù×÷ÈÕÖ¾ | |
Ö§³ÖÅäÖûعö | |
Ö§³Ö ZTP | |
802.3az ÄÜЧÒÔÌ«Íø£¨EEE£© | |
°²È«ºÍ¹ÜÀí | Ö§³Ö ? 802.1x ÈÏÖ¤ |
ÃüÁîÐзּ¶±£»¤¡¢Î´ÊÚȨÓû§ÎÞ·¨ÇÖÈë | |
Ö§³Ö·ÀÖ¹ DOS¡¢ARP ¹¥»÷¹¦ÄÜ¡¢ICMP ·À¹¥»÷ | |
Ö§³Ö¶Ë¿Ú¸ôÀë¡¢¶Ë¿Ú°²È«¡¢Sticky ? MAC | |
Ö§³Ö IP¡¢MAC¡¢¶Ë¿Ú¡¢VLAN µÄ×éºÏ°ó¶¨ | |
Ö§³Ö AAA¡¢Radius¡¢TACACS ? µÈ¶àÖÖÈÏÖ¤·½Ê½ | |
Ö§³Ö RMON | |
»úÏä³ß´ç mm£¨¿í¡ÁÉî¡Á¸ß£© | 442¡Á420¡Á43.6 |
ÂúÅäÖØÁ¿ | 8.05kg |
»·¾³ÒªÇó | ¹¤×÷ζȣº0¡æ¡«40¡æ£¨0m¡«1800m£© ´æ´¢Î¶ȣº-40¡æ¡«+70¡æ |
| Ïà¶Ôʪ¶È£º5%RH¡«95%RH£¬·ÇÄý¶ | |
¹¤×÷µçѹ | AC: ? 90V~290V DC: -38.4V¡«-72V? HVDC: 190V~400V |
µäÐ͹¦ºÄ | 148W |
ÐͺŠ| ÃèÊö |
CM6657F-48S6CQ | CM6657F-48S6CQ ? ½»»»»ú(48*10GE SFP+,6*100GE ? QSFP28,²»º¬µçÔ´·çÉÈ) |
FAN-031A-B | ·ç»úºÐ(B,·ç»úºÐÃæ°å²à³ö·ç) |
FAN-031A-F | ·ç»úºÐ(F,·ç»úºÐÃæ°å²à½ø·ç) |
PAC600S12-EB | 600W½»Á÷µçÔ´Ä£¿é(ºóǰ·çµÀ,µçÔ´Ãæ°å²à³ö·ç) |
PAC600S12-EF | 600W½»Á÷µçÔ´Ä£¿é(ǰºó·çµÀ,µçÔ´Ãæ°å²à½ø·ç) |
PDC1000S12-DB | 1000WÖ±Á÷µçÔ´Ä£¿é(ºóǰ·çµÀ,µçÔ´Ãæ°å²à³ö·ç) |
PDC1000S12-DF | 1000WÖ±Á÷µçÔ´Ä£¿é(ǰºó·çµÀ,µçÔ´Ãæ°å²à½ø·ç) |
PHD1K2S12-DB | 1200W¸ßѹֱÁ÷µçÔ´Ä£¿é(ºóǰ·çµÀ,µçÔ´Ãæ°å²à³ö·ç) |
N1-CM66LIC-CFFD | N1-CM6600½»»»»úCloudFabric FoundationÈí¼þ°ü |
| N1-CM66LIC-CFFD-VxLAN | N1-CM6600½»»»»úCloudFabric Foundation VxLANÈí¼þ°ü |
N1-CM66CFFD-SnS1Y | N1-CM6600½»»»»úCloudFabric FoundationÈí¼þ°ü-Subscription and Support-Äê |